An Examination of the Relationship between Flow Parameters and Symptoms According to Fire Phase in a Mine Model

Main Article Content

Selçuk Keçel

Abstract

This study examines the relationship between temperature, CO dispersions, symptoms, and COHb% levels accumulated in the blood on available ventilation conditions in cases of fire at point in an underground mine model. Based on operating parameters (air velocity and direction) of the ventilation system in the underground mine model, fast growing phase fire analyses were conducted according to the heat release rate (HRR) value in the range of 0-61.34MW. In fire scenarios prepared according to the hydrocarbon fuel type (C2.3H4.2O1.3), boundary conditions were calculated depending on the combustion equation considering fuel lower heating value (Qc). CO dispersions inside the tunnel were examined by transferring the time-dependent boundary conditions to the computational fluid dynamics (CFD) program.  yCO, COHb%, and COHb%/∆t changes were calculated according to the HRR value.  Findings regarding the effects of CO emission (acute and chronic poisoning), were expressed according to the HRR value.

 

Keywords Combustion Model Design, Heat Release Rate (HRR), Carbon Monoxide emission, Symptoms and Survival Time, Computational Fluid Dynamics (CFD);

Downloads

Download data is not yet available.

Article Details

Section
Articles

References

Hansen R, Ingason H. Heat release rate measurements of burning mining vehicles in an underground mine. Fire Safety Journal. 2013;61:12-25.
Isobe M, Helbing D, Nagatani T. Many-particle simulation of the evacuation process from a room without visibility. Physical Review E 2004;69:1-32.
Kirkpatrick JN. Occult carbon monoxide Poisoning. West J Med 1987;146:52–56.
Kobes M, Helsloot I, de Vries B, Post JG. Building safety and human behaviour in fire: A literature review. Fire Safety Journal. 2010;45(1):1-11.
Macmahon GW, O’Daniel JL, Davis LK, Walker RL. CFD Study and structural analysis of the sago mine accident, US Army Corps of Engineers, 2007;1-3, http://arlweb.msha.gov/sagomine/CFDSagoReport.pdf [accessed 05.04.16].
Nagai R, Nagatani T, Isobe M, Adachi T. Effect of exit configuration on evacuation of a room without visibility. Physica A: Statistical Mechanics and its Applications. 2004;343:712-24.
Piantadosi CA. Carbon monoxide Poisoning. Undersea Hyperb Med 2004;31:167–177.
Smollin C, Olson K. Carbon monoxide poisoning (acute). Clinical Evidence 2008;07:2103.
Stewart RD, Stewart RS, Stamm W, Seelen RP. Rapid Estimation of Carboxyhemoglobin Level in Fire Fighters. JAMA 1976;235:390-392.
Tarada F. Fire Hazard Calculations using CFD, 2nd International Conference on Fire Safety in Enclosed Spaces. Geneva 1998.
TBMM Soma Accident Research Report Vol. 1, Turkey, 352-353, 2014.
Walters RN, Hackett SM, Lyonn RE. Heats of combustion of high temperature polymers. Fire And Materials 2000; 24:245–252.
Wang HY. Prediction of soot and carbon monoxide production in a ventilated tunnel fire by using a computer simulation. Fire Safety Journal. 2009;44(3):394-406.